ConnectionPool: fix gun open errors being returned without an error tuple

When gun shuts down due to the host being unreachable, the worker
process shuts down with the same shutdown reason since they are linked.
Gun doesn't have error tuples in it's shutdown reason though, so we need
to handle it in get_conn.

Closes #2008
This commit is contained in:
rinpatch 2020-08-01 17:59:50 +03:00
parent 3a6a4dd77a
commit 45be1fe00e

View file

@ -10,6 +10,7 @@ def children do
]
end
@spec get_conn(URI.t(), keyword()) :: {:ok, pid()} | {:error, term()}
def get_conn(uri, opts) do
key = "#{uri.scheme}:#{uri.host}:#{uri.port}"
@ -54,12 +55,14 @@ defp get_gun_pid_from_worker(worker_pid, register) do
{:DOWN, ^ref, :process, ^worker_pid, reason} ->
case reason do
{:shutdown, error} -> error
{:shutdown, {:error, _} = error} -> error
{:shutdown, error} -> {:error, error}
_ -> {:error, reason}
end
end
end
@spec release_conn(pid()) :: :ok
def release_conn(conn_pid) do
# :ets.fun2ms(fn {_, {worker_pid, {gun_pid, _, _, _}}} when gun_pid == conn_pid ->
# worker_pid end)